Laboratoire d’Analyse et d’Architecture des Systèmes
D.SAYA, T.LEICHLE, J.B.POURCIEL, F.MATHIEU, C.BERGAUD , L.NICU
2I, NBS
Manifestation avec acte : 33rd International Conference on Micro and Nano Engineering (MNE2007), Copenhague (Danemark), 23-26 Septembre 2007, 2p. , N° 07440
Diffusable
Plus d'informations
For the purpose of biochip miniaturization, we developed a liquid spotter-based on silicon microcantilevers incorporating in-plane nanotips as a MEMS nanopatterning tool. We present new fabricated cantilevers with added piezoresistors for the contact force control during deposition. Matrices of droplets of 1 ¼m in diameter were achieved with a 10 ¼m interspot distance with high uniformity and high reproducibility by the nanotip cantilever with piezoresistive force controller.
E.DESCAMPS, T.LEICHLE, B.CORSO, S.LAURENT, P.MAILLEY, L.NICU, T.LIVACHE, C.BERGAUD
CEA Grenoble, NANO
Revue Scientifique : Advanced Materials, Vol.19, N°14, pp.1816-1821, Juillet 2007 , N° 06725
Diffusable
110660P.LOW, N.TAKAMA, B.J.KIM, C.BERGAUD
NANO, CNRS-IIS, University of Tokyo
Manifestation avec acte : The 14th International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers'07 & Eurosensors), Lyon (France), 10-14 Juin 2007, 4p. , N° 07386
Diffusable
110900F.VANDEVELDE, T.LEICHLE, C.AYELA, C.BERGAUD, L.NICU, K.HAUPT
Université Compiègne, NANO
Revue Scientifique : Langmuir, Vol.23, N°12, pp.6490-6493, Mars 2007 , N° 07135
Diffusable
Plus d'informations
We have used fountain pen microlithography to deposit arrays of molecularly imprinted polymer microdots on flat substrates. We visualize analyte binding to the dots by fluorescence microscopy with the aid of fluorescein as a model analyte. Elution and readsorption of the analyte to the MIP dots were possible if the porosity of the dots was improved by a sacrificial polymeric porogen. The imprinting effect was confirmed by using compounds structurally related to fluorescein. In addition, we show with another MIP specific to 2,4-D that, apart from the direct measurement of the binding of fluorescent compounds, a competitive immunoassay-type format can also be used to transduce the binding. We believe that this technique has a strong potential for the fabrication of biomimetic microchips and other types of integrated biosensors.
F.MATHIEU, D.SAYA, C.BERGAUD, L.NICU
2I, NANO
Revue Scientifique : IEEE Sensors Journal, Vol.7, N°2, pp.172-178, Février 2007 , N° 06203
Diffusable
109200D.SAYA, T.LEICHLE, J.B.POURCIEL, C.BERGAUD, L.NICU
NANO, 2I
Revue Scientifique : Journal of Micromechanics and Microengineering, Vol.17, N°1, pp.N1-N5, Janvier 2007 , N° 07137
Diffusable
109603A.VALSESIA, P.COLPO, L.M.LACROIX, F.BRETAGNOL, T.MEZIANI, F.ROSSI, T.LEICHLE, L.NICU, C.BERGAUD
Ispra, NANO
Revue Scientifique : Small, Vol.2, N°12, pp.1444-1447, 2006 , N° 06232
Diffusable
109641T.LEICHLE, E.DESCAMPS, B.CORSO, S.LAURENT, P.MAILLEY, T.LIVACHE, J.B.POURCIEL, C.BERGAUD, L.NICU
NANO, CEA Grenoble, 2I
Manifestation avec acte : 10th International Conference on Miniaturized Systems for Chemistry and Life Sciences (uTAS'2006), Tokyo (Japon), 5-9 Novembre 2006, pp.774-776 , N° 06415
Diffusable
108340N.BERTHET, T.LEICHLE, E.TREVISIOL, J.B.POURCIEL, D.SAYA, C.BERGAUD, L.NICU, J.M.FRANCOIS
INSAT-DGBA, 2I, NANO
Manifestation avec acte : 10th International Conference on Miniaturized Systems for Chemistry and Life Sciences (uTAS'2006), Tokyo (Japon), 5-9 Novembre 2006, pp.1217-1219 , N° 06416
Diffusable
108341T.LEICHLE, D.SAYA, P.BELAUBRE, J.B.POURCIEL, F.MATHIEU, J.P.LAUR, L.NICU, C.BERGAUD
NANO, 2I, CIP, CNRS-IIS
Revue Scientifique : Sensors and Actuators A: Physical, Vol.132, N°2, pp.590-596, Novembre 2006 , N° 05027
Diffusable
109327