Publications personnelle

208documents trouvés

06803
13/07/2007

Optimization of fuzzy controllers by neural networks and hierarchical genetic algorithms

O.GUENOUNOU, A.BELMEHDI, B.DAHHOU

DISCO

Manifestation avec acte : European Control Conference (ECC'07), Kos (Grèce), 2-5 Juillet 2007, pp.196-203 , N° 06803

Diffusable

110746
05022
13/07/2007

Fault isolation for nonlinear dynamic systems based on parameter intervals

Z.LI, B.DAHHOU

DISCO

Revue Scientifique : International Journal of Systems Science, Vol.38, N°7, pp.531-547, Juillet 2007 , N° 05022

Diffusable

Plus d'informations

Abstract

The study of fault detection and isolation for nonlinear dynamic systems has been receiving significant attention. Up to now few literatures pay attention to the speed of fault isolation. However, it is a crucial problem for the design of the fault-tolerant control (FTC) of the nonlinear dynamic systems. In this article a new method of fault isolation for nonlinear dynamic systems is proposed. The method is based on the monotonous characteristic of the prediction error of the observer with respect to singular parameter difference between the system and the observer. The proposed method has the advantage of the methods based on adaptive observers that fits a large kind of nonlinear dynamic systems, while it does not have their disadvantage that take a long time to identify the system parameter: Therefore the fault isolation of this method is quicker. The performance of the method is illustrated by simulation results using a nonlinear dynamic model of an alcoholic fermentation process.

110748
07191
01/05/2007

Actuator fault isolation strategy to a waste water treatment process

D.FRAGKOULIS, G.ROUX, B.DAHHOU

DISCO

Manifestation avec acte : Conference on Systems and Control (CSC 2007), Marrakech (Maroc), 16-18 Mai 2007, 6p. , N° 07191

Diffusable

Plus d'informations

Abstract

In this paper we propose a new actuator fault isolation strategy for a waste water treatment process. The method is based on the creation of a bank of nonlinear observers where each observer isolates the fault of each actuator. The advantage of the method is that we can detect and isolate single and multiple faults. The validity of the method will be tested to waste water treatment process.

110751
06800
19/03/2007

A new neuro fuzzy controller structure for nonlinear systems

O.GUENOUNOU, A.BELMEHDI, B.DAHHOU

DISCO

Manifestation avec acte : Conference on Systems Analysis & Automatic Control (SAC'07), Hammamet (Tunisie), 19-22 Mars 2007, 7p. , N° 06800

Diffusable

109521
07703
01/03/2007

Diagnosis of multi faults in fermentation bioprocess by structural approach

N.BELKHERCHI, A.BELMEHDI, B.DAHHOU

DISCO, LT2I

Manifestation avec acte : International Conference on Systems Analysis and Automatic Control, Hammamet (Tunisie), 19-22 Mars 2007, 5p. , N° 07703

Diffusable

Plus d'informations

Mots-Clés / Keywords
Structural analysis; Diagnosis; Bioprocess; Fault detection; Fault isolation;

112476
06344
01/01/2007

Modelling, software sensors, control and supervision of fermentation processes

B.DAHHOU, G.ROUX, Y.NAKKABI

DISCO, INSAT-DGBA

Ouvrage (contribution) : Fermentation microbiology and biotechnology, Eds. EMT.El-Mansi, CFA.Bryce, AL.Demain, AR.Allman, CRC Taylor & Francis, N°ISBN 0-8493-5334-3, 2007, Chapitre 14, pp.493-522 , N° 06344

Diffusable

109520
06802
17/12/2006

Optimisation de contrôleurs flous par algorithmes génétiques hiérarchisés. Application à la commande d'un bioprocédé

O.GUENOUNOU, A.BELMEHDI, B.DAHHOU

DISCO

Manifestation avec acte : 7ème Conférence Internationale des Sciences et Techniques del'Automatique (STA'2006), Hammamet (Tunisie), 17-19 Décembre 2006, 10p. , N° 06802

Diffusable

109040
06034
01/12/2006

Parameter intervals used for fault isolation in nonlinear dynamic systems

Z.LI, B.DAHHOU

DISCO

Revue Scientifique : International Journal of Modelling, Identification and Control, Vol.1, N°3, pp.215-229, 2006 , N° 06034

Diffusable

Plus d'informations

Abstract

Parameter intervals can be used to solve fault isolation problems. The parameter interval-based fault isolation method has good speed and can provide an estimate of the faulty parameter. In this paper, a parameter interval-based fault isolation method for non-linear dynamic systems is presented.

109341
06801
01/11/2006

Illustration of an interval approach for fault isolation and identification

D.FRAGKOULIS, G.ROUX, B.DAHHOU

DISCO

Rapport LAAS N°06801, Novembre 2006, 8p.

Diffusable

108586
06343
04/10/2006

A fault isolation method for nonlinear dynamic systems based on monotonous observers

Z.LI, B.DAHHOU, G.ROUX

DISCO

Manifestation avec acte : Multiconference on "Computational Engineering in Systems Applications" (CESA'2006), Beijing (Chine), 4-6 Octobre 2006, 8p. , N° 06343

Diffusable

108783