Publications de l'équipe OSE

34documents trouvés

12493
27/06/2012

Robust real-time self-mixing interferometric laser vibration sensor with embedded MEMS accelerometer

U.ZABIT, O.BERNAL, T.BOSCH

OSE

Manifestation avec acte : International Conference on Vibration Measurements by Laser and Noncontact Techniques (AIVELA 2012), Ancona (Italie), 27-29 Juin 2012, pp.148-155 , N° 12493

Lien : http://hal.archives-ouvertes.fr/hal-00733534

Diffusable

Plus d'informations

Abstract

In this paper, we present a real-time implementation of a Self-Mixing (SM) interferometric laser diode (LD) based vibration sensor coupled with an embedded MEMS (microelectromechanical system) accelerometer. Such a sensor allows measuring correct target movements even when the LD based SM sensor is subject to extraneous movements. This results in a vibration sensing system that can be used for embedded applications as there is no more need of keeping the sensor stationary. Such an approach opens the way for the use of such laser sensors in conditions where the use of anti-vibration support is not available or possible. The proposed data fusion between a MEMS accelerometer and a LD based SM sensor results in a robust, compact and low-cost sensing system.

128197
12345
18/06/2012

Vélocimétrie par réinjection optique appliquée à la mesure d'écoulements microfluidiques

L.CAMPAGNOLO

OSE

Manifestation sans acte : Journées Nationales du Réseau Doctoral en Microélectronique (JNRDM 2012), Marseille (France), 18-20 Juin 2012, 4p. , N° 12345

Lien : http://hal.archives-ouvertes.fr/hal-00714049

Diffusable

Plus d'informations

Abstract

Le phénomène de rétro-injection optique (interférences de deux ondes dans le milieu actif d'une diode laser) est utilisé pour des applications métrologiques telles que la mesure de vitesse ou de distance. Dans le cadre de ce projet, cette technologie est appliquée à la mesure de profil d'écoulement dans des puces microfluidiques. L'évolution du signal en fonction de la taille et de la forme du canal microfluidique, du volume de mesure, de la concentration et de la taille des particules est étudiée. Une nouvelle classe de capteurs non invasifs, faible coût et intégrable, est présentée pour la mesure de la microcirculation sanguine in-vivo.

127622
12379
13/05/2012

Real time displacement sensor based on self-mixing interferometry

A.LUNA ARRIAGA, F.BONY, T.BOSCH

OSE

Manifestation avec acte : IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2012), Graz (Autriche), 13-16 Mai 2012, pp.1370-1374 , N° 12379

Lien : http://hal.archives-ouvertes.fr/hal-00716500

Diffusable

Plus d'informations

Abstract

This paper deals with the real time reconstruction of a self-mixing displacement signal under devices with limited resources. By implementing a first-order-hold interpolation used in digital-to-analog converters, the signal recovery problem has been reduced to the efficient usage of an adaptive filter with high potential of parallelism, suitable to meet hard timing constraints, low memory usage and easily integrable with other mitigation algorithms of the physical phenomena proper to laser behavior, towards the creation of a robust embedded displacement sensor.

127717
12285
13/05/2012

Self-mixing sensor for real-time measurement of harmonic and arbitrary displacements

U.ZABIT, O.BERNAL, T.BOSCH

OSE

Manifestation avec acte : IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2012), Graz (Autriche), 13-16 Mai 2012, 5p. , N° 12285

Lien : http://hal.archives-ouvertes.fr/hal-00708480

Diffusable

Plus d'informations

Abstract

A real-time self-mixing laser displacement sensor is presented that uses a fast consecutive-samples based unwrapping algorithm. The processing is achieved at a rate of 125KHz by an integrated micro-converter (ADuC7020) embedded on the SM sensor. Arbitrary and harmonic displacements have been measured in real-time with λ /10 precision as compared with the reference built-in capacitive feedback sensor of the target, where λ is the laser wavelength. The algorithm does not require any parameter estimation or huge memory and corrects possible false fringe detections. This results in a compact, integrated, precise and self-aligned laser sensor that costs less than 40 $.

127401
12380
13/05/2012

Optimization of the performances of a self-mixing velocimeter by using a double laser diode configuration

B.TANIOS, F.BONY, T.BOSCH

OSE

Manifestation avec acte : IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2012), Graz (Autriche), 13-16 Mai 2012, pp.1944-1948 , N° 12380

Lien : http://hal.archives-ouvertes.fr/hal-00716977

Diffusable

Plus d'informations

Abstract

In this paper, we present a self-mixing double-head laser diode velocimeter. Several analyzes are performed to determine the optimal architecture of the double laser diode in terms of accuracy. We demonstrate that the double-head laser diode is insensitive to angle variation contrary to the single laser diode. The accuracy of the double-head laser diode sensor is verified by simulations and experiments.

127719
12294
01/05/2012

Noise-assisted crystallization of opal films

W.KHUNSIN, A.AMANN, G.KOCHER-OBERLEHNER, S.G.ROMANOV, S.PULTEAP, HC.SEAT, E.P.O'REILLY, R.ZENTEL, C.M.SOTOMAYOR TORRES

Tyndall, Glasgow, Erlangen, Silpakorn Univ., OSE, Cork, Mainz (JGU), UAB

Revue Scientifique : Advanced Functional Materials, Vol.22, N°9, pp.1812-1821, Mai 2012 , N° 12294

Diffusable

127421
11820
05/12/2011

High resolution tiltmeters ans strainmeters based on extrinsec fiber Fabbry-Perot interferometry: the LINES project

J.CHERY, J.BOUDIN, M.CATTOEN, HC.SEAT, M.SULEIMAN, P.CHAWAH, G.PLANTIER, A.SOURCE, P.BERNARD, C.BRUNET, S.GAFFET, D.BOYER

Geoscience, CNRS, OSE, LNCMI-T, ESEO, IPGP, LSBB, CNRS

Manifestation sans acte : AGU FALL METTING 2011, San Francisco (USA), 5-9 Décembre 2011 (Résumé) , N° 11820

Diffusable

126625
11865
05/12/2011

Nouvelles chaînes d'instrumentation intégrées multivoies pour l'astrophysique

F.BOUYJOU

OSE

Doctorat : INP Toulouse, 5 Décembre 2011, 218p., Président: J.D.LEGAT, Rapporteurs: P.FOUILLAT, P.NOUET, Examinateurs: O.BERNAL, Directeurs de thèse: H.TAP-BETEILLE, J.A.SAUVAUD, Membre invité: J.M.BIFFI , N° 11865

Lien : http://tel.archives-ouvertes.fr/tel-00766655

Diffusable

Plus d'informations

Mots-Clés / Keywords
Environnement spatial; Chaînes d’instrumentation intégrées; Détecteurs MCP et Semi-conducteurs; Technologie CMOS; ASIC analogique / numérique;

128716
11808
21/11/2011

Vélocimétrie par réinjection optique appliquée à la mesure d'écoulements microfluidiques

L.CAMPAGNOLO, M.NIKOLIC, J.PERCHOUX

OSE, Queensland

Manifestation avec acte : Colloque International Francophone du club CMOI/SFO "Contrôles et Mesures Optiques pour l'Industrie" , Lille (France), 21-25 Novembre 2011, 6p. , N° 11808

Diffusable

126599
11809
21/11/2011

Amélioration d'un capteur optoélectronique embarqué par interférométrie à rétro-injection optique

U.ZABIT, O.BERNAL, T.BOSCH

OSE

Manifestation avec acte : Colloque International Francophone du club CMOI/SFO "Contrôles et Mesures Optiques pour l'Industrie", Lille (France), 21-25 Novembre 2011, 6p. , N° 11809

Diffusable

126601
Pour recevoir une copie des documents, contacter doc@laas.fr en mentionnant le n° de rapport LAAS et votre adresse postale. Signalez tout problème de fonctionnement à sysadmin@laas.fr. http://www.laas.fr/pulman/pulman-isens/web/app.php/